Sound Speed Measurement for Carbon Dioxide Near the Critical Region |
ZHENG Rong-wei1,2,FENG Xiao-juan2,WU Si3,ZHAO Xin-yue1,2,ZHANG Jin-tao2,HUAN Ke-wei1 |
1. College of Science, Changchun University of Science and Technology, Changchun, Jilin 130022, China
2. National Institute of Metrology, Beijing 100029, China
3. Construction Quality Supervision Station of Navy, Beijing 100161, China |
|
|
Abstract Using a cylindrical acoustic resonator, the speed of sound in CO2 at the temperature from 303.10~303.18 K and pressure from 3.855~7.534 MPa is measured. The relative uncertainty of the speed of sound in CO2 is 0.035% at pressure lower than 7.1 MPa and 0.15% at pressure higher than 7.3 MPa. The relative deviation between present data and the calculation from the equation of state is 0.005%~-0.4%. The measurement results can be used to improve the equation of the state of CO2. The experimental system and method can be used in the measurement of CO2 and other working fluids in a wider temperature range in the next future.
|
Received: 08 October 2016
Published: 28 December 2016
|
|
|
|
|
[1]康丽娜, 尚会建, 郑学明. CO2的捕集封存技术进展及在我国的应用前景[J]. 化工进展, 2010, 29(S1):24-27.
[2]NIST. Proceedings of the Workshop on Future Large CO2 Compression Systems[R].NIST, 2009.
[3]Shariatinasab R,Ghayur Safar J, Falaghi H. A New Equation of State for Carbon Dioxide Covering the Fluid Region from the Triple-Point Temperature to 1100 K at Pressures up to 800 MPa[J]. Journal of Physical & Chemical Reference Data, 1996, 25(6):1509-1596.
[4]杨日福,丘泰球.超临界CO2流体中超声速的特性[J].声学技术,2006,25(5):431-435.
[5]罗奔毅,卢义刚.超临界点附近二氧化碳流体的声速[J].物理学报,2008,57(7):4397-4401.
[6]Moldover M R, Trusler J P M, Edwards T J, et al. Measurements of the universal gas constant R using a spherical acoustic resonator[J]. Journal of Research of the National Bureau of Standards,1988,93(2):85-144.
[7]Podesta M D, Underwood R, Sutton G, et al. A low-uncertainty measurement of the Boltzmann constant[J]. Metrologia,2013,50(4):354-376.
[8]Pitre L, Sparasci F, Truong D, et al. Measurement of the Boltzmann constant kB using a quasi-spherical acoustic resonator [J]. International Journal of Thermophysics,2011,32(9):1825–1886.
[9]Gavioso R M, Madonna Ripa D, Steur P P M, et al. A determination of the molar gas constant R by acoustic thermometry in Helium [J]. Metrologia,2015,52(5):274-304.
[10]Lin H, Feng X J, Gillis K A, et al. Improved determination of the Boltzmann constant using a single, fixed-length cylindrical cavity[J]. Metrologia,2013,50(5):417-532.
[11]尹钊玮, 冯晓娟, 林鸿,等. 高压气体声速精密测量系统的研制与测试[J]. 仪器仪表学报, 2013, 34(4):774-779.
[12]Trusler J P M. Physical acoustics and metrology of fluids[M]. Bristol:Adam Hilger Ltd, 1991.
[13]Zhang J T,Lin H,Feng X,et al. Progress toward re-determining the Boltzmann constant with a fixed-path-length cylindrical resonator[J]. International Journal of Thermophysics, 2011. 32(7): 1297-1329.
[14]尹钊玮,冯晓娟,林鸿,等.非连续边界层对圆柱声学共振频率的影响研究 [J]. 计量学报,2014,35(1): 1-4.
[15]冯晓娟, 林鸿, 刘强,等.圆柱定程干涉法声速测量原理与实验系统研制[J].工程热物理学报,2011,32(5):725-728.
[16]伍肆.精密流体声速测量系统研制及高压CO2声速研究[D].武汉:华中科技大学,2015. |
|
|
|