Monte Carlo Simulation of Physical Parameters for Air Kerma Measurement by Graphite Pancake Ionization Chamber |
WANG Kun1,LI Tao2,JIN Sun-jun1,YANG Xiao-yuan1,FAN Tie-shuan2 |
1. National Institute of Metrology, Beijing 100029, China
2. Institute of Heavy Ion Physics, School of Physics, Peking University, Beijing 100871, China |
|
|
Abstract In order to establish the air kerma primary standard based on a graphite pancake ionization chamber for 60Co gamma rays, the radiation field and related physical parameters of the chamber are calculated by the Monte Carlo simulation method. The γ-ray energy spectra and fluence distributions are calculated by the model built by BEAMnrc code, the parameters of the graphite pancake ionization chamber in 60Co γ-ray radiation filed are calculated by EGSnrc code. The combined standard uncertainty of the parameters of the chamber calculated by Monte Carlo method is 0.20%, the results of simulation are accord with results of the same structural chamber from the ARPANSA in the region of the uncertainty. And the change of the values with the primary standard based on a sphere-cylindrical graphite ionization chamber is under expected.
|
Received: 26 November 2014
Published: 29 July 2016
|
|
|
|
|
[1]Allisy-roberts P J, Bruns D T, Kessler C, et al. Dosimetry comparisons and calibrations at the BIPM 2011 to 2013 [R]. Report CCRI(I)/13-07, BIPM, 2013.
[2]Allisy-roberts P J, Bruns D T, Buermann L, et al. Comparisons of the standards for air kerma of the PTB and the BIPM for 60Co and 137Cs gamma radiation [R]. Report CCRI(I)/ 05-10, BIPM, 2005.
[3]Laitano R F, Toni M P, Pimpinella M, et al. Determination of the Kwall correction factor for a cylindrical ionization chamber to measure air-kerma in 60Co Gamma Beams [J]. Phys Med Biol, 2002, 47(3): 2411-2431.
[4]Allisy-roberts P J, Bruns D T, Kessler C, et al. Summary of the BIPM.RI(I)-K1 comparison for air kerma in 60Co gamma radiation [J]. Metrologia, 2007, 44(4):06006-06009.
[5]王坤,李涛,杨小元. 60Co水吸收剂量的量值复现和国际比对验证[J]. 中国医学物理杂志,2013,30(6): 4476-4479.
[6]Rogers D W O, Bielajew A F. Wall attenuation and scatter corrections for ion chambers: measurements versus calculations [J]. Phys Med Biol, 1990, 35(5): 1065-1078.
[7]Boutillon M. g values from Berger and Seltzer tables (1982) [R]. Report CCEMRI (I) /85-18, BIPM, 1985.
[8]Rogers D W O. Uncertainties in the 60Co graphite to air stopping-power ratio and a re-evaluation of (W/e)air values [R]. NRC Report PIRS-363, Ottawa, 1993.
[9]Higgins P D, Attix F H, Hubbell J H, et al. Mass energy-transfer and mass energy-absorption coefficients, including in flight positron annihilation for photon energies 1 keV to 100 MeV [R]. Report NISTIR-4812, NIST, 1992.
[10]Rogers D W O, Treurniet J. Monte-Carlo calculated wall and axial non-uniformity corrections for primary standards of air kerma [R]. Report CCRI(I)/99-06, BIPM, 1999.
[11]Allisy-roberts P J, Boutillon M, Boas J F, et al. Comparison of the air kerma standards of the ARPANSA and the BIPM for 60Co γ rays [R]. Report BIPM-98/4, BIPM, 1998.
[12]Allisy-roberts P J, Bruns D T, Kessler C, et al. Comparison of the standards for air kerma of the NIM and the BIPM for 60Co gamma radiation [J]. Metrologia, 2009, 46(6):06013-06017.
[13]胡家成,杨小元,杨元第,等. 球形石墨空腔电离室壁修正因子的测量与验证 [J]. 中华放射医学与防护杂志, 2005, 25(6):561-564. |
|
|
|