Duct Perturbations to the Radial Modes of Cylindrical Resonators |
ZHANG Fang1,ZHAN Ke-tao1,FENG Xiao-juan2,LIN Hong2,ZHANG Jin-tao2 |
1.College of Science, Beijing University of Chemical Technology, Beijing 100013,China
2.National Institute of Metrology, Beijing 100013,China |
|
|
Abstract Correcting the effect of the fill duct for gas-in and out is very necessary for Boltzmann constant kB measurement. The duct perturbations for ideal radial resonance modes of the cylindrical acoustic resonator were studied, and the various acoustic impedances of duct due to different ways of connection at the end of the duct were analyzed,The perturbations for the resonance frequency and the half width were calculated to be Δf/f0≈-0.04×10-6 and Δg/f0≈14.15×10-6 respectively. The influences for perturbations of the ideal radial resonance modes due to the changes of length, internal diameter and fixed-position of duct were also analyzed.
|
|
|
|
|
|
[1]Mills I M, Mohr P J, Quinn T J, et al. Redefinition of the kilogram, ampere, kelvin and mole: a proposed approach to implementing CIPM Recommendation 1 (CI-2005)[J]. Metrologia, 2006, 43(3): 227-246.
[2]Moldover M R.Optimizing acoustic measurements of the Boltzmann constant[J].Comptes Rendus Physique, 2009, 10(9): 815-827.
[3]Moldover M R, Trusler J P M, Edwards T J, et al.Measurement of the Universal Gas-Constant R Using a Spherical Acoustic Resonator[J]. Phys Rev Lett, 1988, 60(4): 249-252.
[4]Trusler J P M.Pysical Acoustics and Metrology of Fluids[M].London:Taylor & Francis, 1991, 52-65.
[5]Kirchhoff G.On the influence of heat conduction in a gas on sound propagation[J]. Ann Phys Chem, 1868, (134): 177-193.
[6]Gillis K A, Mehl J B, Moldover M R.Theory of the Greenspan Viscometer[J]. J Acoust Soc Am, 2003, 114(1):166-173.
[7] Gillis K A, Lin H, Moldover M R.Perturbations From Ducts on the Modes of Acoustic Thermometers[J]. J Res Natl Inst Stand Technol, 2009, 114(5): 263-285.
[8]Lin H, Gillis K A, Zhang J T.The Opening Perturbation on Acoustic Cylinder Resonance[C]//NIM·CSM. International Conference on Temperature and Thermal Measurements. Beijing, China, 2008. |
|
|
|