Autonomous Algorithm for Relative Error of Smart Electric Energy Meter Cluster |
GUO Jing-tao1,2,ZHANG Ren2,JIN Zhi-gang3 |
1.School of Computer Science and Technology, Tianjin University, Tianjin 300072, China
2.Tianjin Institute of Metrological Supervision and Testing, Tianjin 300192, China
3.School of Electronic and Information Engineering, Tianjin University, Tianjin 300072, China |
|
|
Abstract A tree topology electric energy meter cluster is demonstrated, giving the premise of energy conservation, providing any meter relative error, all the other meters relative errors can be accomplished according to a group of meter readings.This method for meter relative error requires no extra standard instrument.A virtual branch and a virtual load are introduced to present meter power consumption, leaked current power consumption and line resistor consumption.According to law of energy conservation, the problem is transformed to solving a linear or quadratic equation group and numeric method is employed.This algorithm needs the aid of data base with historical readings.Remote automatic reading function of smart meter makes the algorithm applicable.And the algorithm can reduce the cost for maintaining of the meters and help to determine the meters serving time scientifically.The experiment shows that the range of result error is about 0.6%.
|
|
|
|
|
|
[1]E.m. Technical Committee PEL/13, BSI.BS EN 62053-11: 2003 Electricity metering equipment (a.c.) — Particular requirements — Part 11: Electromechanical meters for active energy (classes 0.5 1 and 2)[S]. 2003.
[2]国家质量监督检验检疫总局.JJG 307—2006机电式交流电能表[S].2006.
[3]蓝永林.JJG 307—2006《机电式交流电能表》实施指南[M].北京:中国计量出版社,2006.
[4]国家质量监督检验检疫总局. JJG 596—1999电子式电能表[S]. 1999.
[5]E.m.Technical Committee PEL/13, BSI.BS EN 62052-11:2003 Electricity metering equipment (a.c.) — General requirements,tests and test conditions — Part 11:Metering equipment[S]. 2003.
[6]E.m.Technical Committee PEL/13, BSI.BS EN 62053-21:2003 Electricity metering equipment (a.c.) — Particular requirements — Part 21: Static meters for active energy (classes 1 and 2)[S]. 2003.
[7]毛晓波,黄云峰,黄俊杰.高精度电能表现场校验仪设计[J].电力自动化设备,2007,27(7):69-73.
[8]何绘宇,丘文昌.远程校准系统通用环境的分析与设计[J].软件导刊,2009,8(1):109-110.
[9]Espina P I.Flow Tele-Metrology[J].Instrumentation and Measurement Technology Conference, 1999, 2(2): 614-617.
[10]Amicone D, Bernieri A, Betta G.On the Remote Calibration of Electrical Energy Meters[C]//16th IMEKO TC4 Symposium Exploring New Frontiers of Instrumentation and Methods for Electrical and Electronic Measurements, Florence, Italy, 2008,22-24 .
[11]Albu M M, Ferrero A, Mihai F.Remote Calibration Using Mobile, Multi-agent Technology[J].IEEE Transactions on Instrumentation and Measurement, 2005,2 (54) :24-30.
[12]Kreis T, Jüptner W, Schnars U.Tele-Metrology Based on Digital Holography[M].New York:Springer US,2006.
[13]Espina P I.Tele-Metrology: Remote Flow Meter Calibration[J].Flow Control Magazine. 1999,5 (1) :16-21.
[14]Albert R K, Albert I N, Nakarado G L.Structural vulnerability of the North American power grid[J].Physical Review E, 2004,69(2) :025103.
[15]余贻鑫.智能电网的技术组成和实现顺序[J].南方电网技术,2009,3(2):1-6.
[16]Crucitti P, Latora V, Marchiori M.A topological analysis ofthe Italian electric power grid[J].Physicia A, 2004,338(1-2) :92-97.
[17]李庆扬,王能超,易大义.数值分析[M].北京:清华大学出版社,施普林格出版社,2001.
[18]程云鹏,张凯院,徐仲.矩阵论[M].西安:西北工业大学出版社,2002. |
|
|
|