A Method for Calibration of Electronic Current Transformer |
PAN Feng1, SHEN Yan-hua2, XIAO Yong1, SUN Wei-ming1, ZHAO Wei1, ZHANG Yong-wang1 |
1. Electric Power Research Institute of Guangdong Power Grid Corporation, Guangzhou, Guangdong 510080, China;
2. South China University of Technology, Guangzhou, Guangdong 510640, China |
|
|
Abstract A method based on the sampling measurement technology for calibration of electronic current transformer with analog and digital outputs is described.The ratio and phase errors of the current transformer under calibration are determined as the difference between the two measurement values that are collected at the secondary of the calibrated transformer and of a reference transformer when the same signal is applied to their primary. The error of the method is thoroughly analyzed and the possibility is proved. A prototype of calibration system for electronic current transformer has been developed. The test that estimates the performance of the calibration system has been carried out in National Center for High Voltage Measurement. The tested results show that the system fulfills the requirements for calibrating current transformers for use with electrical measuring instruments and with accuracy class up to 0.2.
|
|
|
|
|
[1] 宁红伟,杨以涵,李静,等.互感器校验装置综述[J]. 电力系统保护与控制, 2009, 37(10): 131-135.
[2] 刘庆余. 互感器校验仪的原理与整体检定[M]. 北京:中国计量出版社, 2003.
[3] GB/T 20840.8—2007 电子式电流互感器[S].
[4] Brandolini A, Faifer M, Ottoboni R. A simple method for calibration for the traditional
and electronic measurement current and voltage transformers[J]. IEEE Transactions on Instrumentation and Measurement, 2009, 58(5): 1345-1353.
[5] 郭伟, 张红超, 于朝辉. 电子式互感器模拟输出校准系统[J]. 电力系统保护与控制,2010, 38 (6): 49-51.〖JP〗
[6] Moreau C, Grellier J M. Method and test equipment for accuracy measurement of high
voltage electronic transducers with digital output[C]//11th International Symposium on
High-Voltage Engineering (ISH 99),London, UK,1999.
[7] 余春雨, 叶国雄, 王晓琪, 等. 电子式互感器的校准方法与技术[J]. 高电压技术, 2004,30(4): 20-24.
[8] 尚秋峰, 杨以涵,高桦. 一种高准确度有源光学电流互感器的研制与校验[J].电工技术学报, 2005, 20(3): 105-110.
[9] JJG 313—2010 测量用电流互感器检定规程[S].
[10] Pan F, Xu Y, Xiao X, et al. Calibration system for electronic instrumenttransformers with analogue and digital outputs[C]//The 9th International Conference on Electronic Measurement & Instruments (ICEMI 2009), Beijing, China, 2009. |
|
|
|