The On-line Measurement of Surface TemperatureBased on High Emissivity Target |
WANG Ze-yao,CHEN Le,FU Ya-qiong,WU Yun-xia,XU Jian-bin |
Zhejiang Provincial Key Laboratory of On-line Testing Equipment Calibration Technology Research,China Jiliang University, Hangzhou, Zhejiang 310018, China |
|
|
Abstract In some industrial fields, surface temperature measurement requires speed and accuracy. Using infrared thermometer to measure temperature directly is fast, but the accuracy is low. Based on a target of high emissivity, a method of measuring the surface temperature fast and accurately is proposed. The target which made by high emissivity paint can help eliminate the surface emissivity effects on the accuracy of infrared temperature measurement when used in site. At the same time, the influence of ambient temperature, atmospheric temperature, measuring distance, atmospheric attenuation and other factors can be eliminated by comparing the direct measurement and target measurement results. Experimental results and theoretical analysis show that the proposed method can effectively improve the accuracy of infrared surface temperature measurement and the average error of the method is lower than 1%.
|
Received: 01 December 2014
Published: 10 December 2015
|
|
Corresponding Authors:
Le Chen
E-mail: clcjlu@126.com
|
|
|
|
[1]陈亮. 红外热像组件成像测温系统研究[D].杭州:中国计量学院,2010.
[2]戴景明. 辐射测温的发展现状与展望[J].自动化技术与应用,2004,23(3):1-6.
[3]戴景民,王新北. 材料发射率测量技术及其应用[J].计量学报,2007,28(3):232-236.
[4]杨立. 红外热像仪测温计算与误差分析[J].红外技术,1999, 21(4):20-24.
[5]戴苏明,朱桂荣. 红外测温误差的来源与分析[J].苏州丝绸工学院学报,2000,20(1):25-29.
[6]张健, 扬立, 刘慧开. 环境高温物体对红外热像仪测温误差的影响[J].红外技术, 2005, 27(5): 419-422.
[7]崔志尚,盛健,Battuello M,等. 一种根据被测对象的真实温度检定红外温度计的新方法[J].计量学报,2002,23(2):113-115.
[8]曹欣荣,戴景民. 环境温度对红外辐射式体温计读数的影响[J].计量学报,2002,23(1):33-35.
[9]包学诚,刘健,张幼文,等. 提高红外测温精度的分析研究[J].计量学报,1990,11(3):195-198.
[10]张建镛,易庆祥,王强,等.常温黑体辐射标准[J].计量学报,1989,10(1):1-7. |
|
|
|