International Key Comparison of Shock Acceleration and Determination of the Reference Value |
HU Hongbo,BAI Jie,SUN Qiao |
National Institute of Metrology, Beijing 100029, China |
|
|
Abstract The National Institute of Metrology, as pilot laboratory for the first international key comparison for shock acceleration(CCAUV.V-K4) is proposed. Technical protocol is illustrated by combination of dynamic characteristics of shock acceleration measuring chain and spectral contents of shock excitation. Three different approaches are used to calculate the reference value of comparison, including recommended method by international comparison and two methods based on Bayesian inference. It is argued that Bayesian approach with different statistical model is compatible with the practice of metrology, with different prior distribution and MCMC method to obtain the posterior distribution. The equivalence and divergence of three methods are illustrated through comparison of results obtained.
|
Received: 26 September 2022
Published: 22 January 2024
|
|
|
|
|
[6] |
于梅, 胡红波, 左爱斌, 等. 新一代冲击加速度国家基准装置的研究与建立[J]. 振动与冲击, 2013, 32(10):124-129.
|
[7] |
孙桥, 王建林, 胡红波, 等. 低g值碰撞式冲击加速度计量标准装置的研究与建立[J]. 振动与冲击, 2015, 34(10):179-183.
|
[11] |
白杰, 胡红波. 计量中回归模型参数值及其不确定度评估[J]. 计量学报, 2022, 43(12): 1683-1688.
|
[20] |
韦来生, 张伟平. 贝叶斯分析[M]. 合肥:中国科学技术大学出版社, 2015, 187-242.
|
[4] |
SUN Q, VELDMAN I. Final report on key comparison APMP.AUV.V-K3[J]. Metrologia, 2013, 50(1A), 09001.
|
[10] |
胡红波, 孙桥. 基于绝对法冲击校准的加速度计参数辨识研究[J]. 测试技术学报, 2013, 27(1):19-24.
|
[2] |
王春艳. 加快国家校准与测量能力的互认[J]. 中国计量, 2013(5):44-45.
|
[13] |
COX M G. The evaluation of key comparison data [J]. Metrologia, 2002, 39(3):589-595.
|
[1] |
BIPM. Mutual Recognition of national measurements standards and of calibration and measurement certificates issued by national metrology institutes[R]. Bureau International des Poids at Mesures: Paris: 1999.
|
[3] |
SUN Q, YANG L F, CLAIRE B, et al. Final report of CCAUV.V-K3: Key comparison in the field of acceleration on the complex charge sensitivity[J]. Metrologia, 2017, 54(1A), 09001.
|
[5] |
胡红波, 孙桥, 黄宇中. 不同冲击激励系统绝对法冲击校准比对可行性的研究[J]. 振动与冲击, 2012, 31(20):27-31.
|
|
SUN Q, WANG J L, HU H B, et al. Development of a low-g shock standard device based on rigid body collision for shock acceleration calibration[J]. Journal of vibration and shock, 2015,34(10):179-183.
|
[8] |
SUN Q, HU H B, AKIHIRO OTA, et al. Key comparison in the field of acceleration on low intensity shock sensitivity[J]. Metrologia, 2019,56(1A),09003.
|
|
JIANG W S,YIN X,LI H Y,et al. Dynamic Calibration Method of a Force Transducer Based on Parameter Identification[J]. Acta Metrologica Sinica, 2021, 42(5): 603-608.
|
|
HU H B, SUN Q. Parameter identification of accelerometer based on primary shock calibration method[J]. Journal of test and measurement technology, 2013,27(1):19-24.
|
[14] |
STEELE A G, HILL K D, DOUGLAS R J. Data pooling and key reference values[J]. Metrologia, 2002, 39(3):269-277.
|
[16] |
TOMAN B. Bayesian approaches to calculating a reference value in key comparison experiments[J]. Technometrics, 2007, 49(1):81-87.
|
[18] |
COULON R, JUDGE S. An evolutionary algorthim for consensus building in inter-laboratory comparisons[J]. Metrologia, 2021, 58 (6):1-11.
|
|
HU H B, SUN Q, HUANG Y Z. Comparing feasibility for primary method of shock calibration with different shock exciters[J]. Journal of vibration and shock, 2012, 31(20):27-31.
|
|
BAI J, HU H B. Estimates and Its Corresponding Uncertainty Evaluation of Parameters for Regression Model in Metrology[J]. Acta Metrologica Sinica, 2022, 43(12): 1683-1688.
|
|
HU H B, YANG L F, YU M. Study on key technologies of vibration calibration using Homodyne interferometer[J]. Acta Metrological Sinica, 2018, 39(3):368-372.
|
[19] |
BIPM, IEC, IFCC, ISO, IUPAC, IUPAP and OIML, Guide to the Expression of Uncertainty in Measurement. International Organization for Standardization, Guide to the Expression of Uncertainty in Measurement[S]. 2008.
|
|
YU M, HU H B, ZUO A B, et al. Establishment of new generation national primary standard device for shock acceleration calibration[J]. Journal of vibration and shock, 2013, 32(10):124-129.
|
[9] |
江文松, 尹肖, 李泓洋, 等. 基于参数辨识的力传感器动态校准方法[J]. 计量学报, 2021, 42(5): 603-608.
|
[12] |
胡红波, 杨丽峰, 于梅. 零差干涉仪用于振动校准中关键技术的研究[J]. 计量学报, 2018, 39(3):368-372.
|
[15] |
KACKER R N, DALTA R U, PARR A C. Statistical analysis of CIPM key comparisons based on the ISO GUIDE[J]. Metrologia, 2004, 41(4):340-352.
|
[17] |
COX M G, HARRIS P M. The evaluation of key comparison data using comparison reference curves[J]. Metrologia, 2012, 49(4):437-445.
|
|
|
|