Research on Time Domain Measurement Method of Broadband Grounded Coplanar Waveguides |
ZHU Jiang-miao1,WAN Zhao-tong1,ZHAO Ke-jia2,WANG Peng-fei1,ZHANG Meng-meng1 |
1.Faculty of Information Technology,Beijing University of Technology,Beijing 100124, China
2.National Institute of Metrology,Beijing 100029,China |
|
|
Abstract The broadband grounded coplanar waveguide (GCPW) is the core component for calibrating oscilloscope broadband probes. To accurately measure the bandwidth of the oscilloscope probe, obtaining the transmission characteristics of the broadband GCPW becomes the key to achieving high-precision calibration. A GCPW time-domain twice measurement system is constructed based on femtosecond laser excitation picosecond electric pulse technology in the measuring principle of time-domain automatic network analyzer(TDANA). This involves taking two measurements in the system to solve the impulse response of the broadband GCPW(twice measurement method), thereby the frequency domain bandwidth can be obtained. The GCPW is designed with a post-wall structure (vias placed along the signal trace), and the processed sample is measured by the twice measurement method. In this way, the 3dB bandwidth of our sample reaches 54.2GHz, which greatly agrees with the simulation result. The calibrated broadband GCPW can be used as a standard device for calibrating broadband probes, and its measured results can be effectively traced to the national benchmark for pulse waveform parameters.
|
Received: 14 July 2022
Published: 17 November 2023
|
|
|
|
|
|
Zhao K J, Yang Z J, Wu Z C, et al. Improvement and Development of the Traceability System of Pulse Waveform Parameter Values [J]. Measurement Technique, 2020(5): 60-67.
|
[11] |
孙圣和, 刘明亮, 施正豪. 现代时域测量[M]. 哈尔滨: 哈尔滨工业大学出版社, 1989.
|
[10] |
朱江淼, 李然, 缪京元, 等. 应用脉冲参数国家基准校准Agilent 86100C宽带取样示波器[J]. 北京工业大学学报, 2012, 38(12): 1798-1803.
|
|
LAN J. Frequency Domain Measurement and Time Domain Measurement in Microwave Measurement [J]. Silicon Valley, 2012, 8: 187, 66.
|
|
Liu G D. Calibration Accuracy and Choice of the Oscilloscope Probe [J]. Electronic Instrumentation Customer, 2006, 13(3): 128-130.
|
|
Zhang N, Zhu S J, Chen Y S. The Calibration Technique Discussion of Oscilloscope Probe [J]. China Measurement & Test, 2004, 30(5): 35-36.
|
[3] |
Zhu J M, Zheng X Y, Zhao K J, et al. Research on Grounded Coplanar Waveguide for Calibration of Digital Real-time Oscilloscope Probe [C]//2021 IEEE 15th International Conference on Electronic Measurement & Instruments (ICEMI), Nanjing, China, 2021: 194-199.
|
[5] |
Sorensen M, Marathe S, Pommerenke D, et al. Design of TEM Transmission Line for Probe Calibration up to 40 GHz [C]]//2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity(EMC, SI & PI), Long Beach, CA, USA , 2018: 640-644.
|
[6] |
李谦若. 网络分析仪时域测量的介绍及应用[C]//高品质射频电缆技术研讨会暨光电线缆分会第八次专家组会议论文集. 2009: 47-53.
|
[12] |
刘明亮, 陆福敏, 朱江淼, 等. 现代脉冲计量[M]. 北京: 科学出版社, 2010.
|
[4] |
Wei X C. Design of Microstrip Line used for Probe Calibration up to 40 GHz [C]//2021 13th Global Symposium on Millimeter-Waves & Terahertz(GSMM), Nanjing, China, 2021: 1-3.
|
|
Sun J, Liu C, Liang F G, et al. Extracting S-Parameter of Two-port Network by Using One-port Calibration Error Term of Vector Network Analyzer[J]. Acta Metrologica Sinica, 2021, 42 (11): 1499-1503.
|
|
Zhu J M, Li R, Miao J Y, et al. Calibrating Agilent 86100C Broadband Sampling Oscilloscope Using Pulse Parameter National Standard [J]. Journal of Beijing University of Technology, 2012, 38(12): 1798-1803.
|
|
Xu S F, Zhao W. Broadband Dielectric Constant Extraction Method Based on Coplanar Waveguide Transmission Line[J]. Acta Metrologica Sinica, 2022, 43 (8): 984-988
|
[15] |
Jackson R W. Mode conversion at discontinuities in finite-width conductor-backed coplanar waveguide [J]. IEEE Transactions on Microwave Theory and Techniques, 1989, 37(10): 1582-1589.
|
[19] |
Zhou Z, Melde K L. Development of a Broadband Coplanar Waveguide-to-Microstrip Transition With Vias [J]. IEEE Transactions on Advanced Packaging, 2008, 31(4): 861-872.
|
[1] |
刘光德. 示波器探头的选择与校准[J]. 仪器仪表用户, 2006, 13(3): 128-130.
|
[2] |
张楠, 朱思捷, 陈益胜. 示波器探头校准方法探讨[J]. 中国测试技术, 2004, 30(5): 35-36.
|
[8] |
孙静, 刘晨, 梁法国, 等. 利用矢量网络分析仪单端口校准误差项提取二端口网络的S参数[J]. 计量学报, 2021, 42 (11): 1499-1503.
|
[9] |
赵科佳, 杨智君, 吴昭春, 等. 脉冲波形参数量值溯源体系的完善与发展[J]. 计量技术, 2020(5): 60-67.
|
[14] |
李玉福. 过孔阵列共面波导和共面带线传输特性及应用研究 [D]. 南京: 东南大学, 2017.
|
[16] |
Sain A, Melde K L. Impact of Ground via Placement in Grounded Coplanar Waveguide Interconnects [J]. IEEE Transactions on Components, Packaging and Manufacturing Technology, 2016, 6(1): 136-144.
|
[7] |
兰娇. 微波测量中的频域测量与时域测量[J]. 硅谷, 2012, 8: 187+66.
|
[13] |
徐森锋, 赵伟. 基于共面波导传输线的宽频带介电常数提取方法[J]. 计量学报, 2022, 43 (8): 984-988
|
[17] |
Yu M, Vahldieck R, Huang J. Comparing coax launcher and wafer probe excitation for 10 mil conductor backed CPW with via holes and airbridges [C]//I993 EEE MTT-S International Microwave Symposium Digest, Atlanta, GA, USA, 1993: 705-708.
|
[18] |
Haydl W H. On the use of vias in conductor-backed coplanar circuits [J]. IEEE Transactions on Microwave Theory and Techniques, 2002, 50(6): 1571-1577.
|
[20] |
Yuasa T, Nishino T, Oh-Hashi H. Simple design formula for parallel plate mode suppression by ground via-holes [C]//2004 IEEE MTT-S International Microwave Symposium Digest. Fort Worth, TX, USA, 2004: 641-644.
|
|
|
|