An Equivalent Method for Simulating Anesthetic Gas Based on Infrared Absorption Spectroscopy |
DING Xiang1,MA Xue-ran1,ZHANG Yang2,LI Wen-hua2,ZHOU Feng1 |
1. National Institute of Metrology, Beijing 100029, China
2. Anhui Young-Hearty Medical Equipment Co., Ltd, Anqing, Anhui 231400, China |
|
|
Abstract Calibration of anesthetic gas detector relies on the use of standard anesthetic gases, but its preparation is costly and time consuming. To solve this problem, an equivalent simulation method for anesthetic gases is proposed. Infrared filters are used to simulate the absorption of infrared light by anesthetic gases at different concentrations and serve as standard anesthetic gas. An anesthetic gas detection system is developed. Sevoflurane gases with volume fractions between 0.23%~8.50% and infrared filters with transmittance between 36%~95% are prepared and measured. It is demonstrated that the repeatability error of the equivalent sevoflurane concentration of filters is small than 0.02% and the maximum variation of equivalent concentration induced by the temperature effect is small than 0.02%+1.5%·c (c is the volume fraction of the measured gas). It is proved that infrared filters can be used to simulate standard anesthetic gases.
|
Received: 17 May 2022
Published: 10 October 2023
|
|
|
|
|
|
Yu H W, Xu Y Y, Chen X L, et al. Study on the infrared spectrum of fluothane[J].Organo-Fluorine Industry, 2019(4):30-33.
|
[3] |
张帆, 张立萍. 红外吸收光谱法在气体检测中的应用[J]. 唐山师范学院学报, 2005, 27(5):62-64.
|
[12] |
于宏伟, 徐元媛, 陈新乐,等. 氟烷红外光谱的研究[J]. 有机氟工业, 2019(4):30-33.
|
[2] |
吕洪震, 马若梦, 张亮,等. 基于傅里叶红外光谱仪的高温含水烟气中低浓度一氧化氮精确测量研究[J]. 计量学报, 2021, 42(4):526-531.
|
[1] |
盛伟岸, 张立权, 黄帅,等. 基于RBF神经网络的生物质电站高温气体CO2浓度测量方法[J]. 计量学报, 2021, 42(1):111-116.
|
[7] |
刘强, 尧德中, 李新胜,等. 基于NDIR技术的麻醉气体浓度检测装置[J]. 医疗卫生装备, 2005, 26(7):26-27.
|
[6] |
刘岩峰. 麻醉气体浓度检测方法的研究及改进[J]. 中国医药科学, 2013, 3(6):155-158.
|
[13] |
余怀之. 红外光学材料[M]. 北京:国防工业出版社, 2015.
|
[14] |
吴雅颂. 锗单晶红外透射特性的探讨[J]. 云南冶金, 1991(5):30-36.
|
|
Sheng W A, Zhang L Q, Huang S, et al. CO2 concentration method in high temperature gas of biomass power plant based on RBF neural network[J]. Acta Metrologica Sinica, 2021, 42(1):111-116.
|
[4] |
Ambrisko T D, Klide A M. Comparison of use of an infrared anesthetic gas monitor and refractometry for measurement of anesthetic agent concentrations[J]. American Journal of Veterinary Research, 2011, 72(10):1299-1304.
|
|
Liu Y F. Research and improvement of the method of detecting anesthetic gas concentration[J].China Medicine and Pharmacy, 2013, 3(6):155-158.
|
[8] |
Abdelkhalik A, Makhlouf G, Hassan M A. A new implementation of EN1839 method T mixture preparation to prepare calibration gas mixtures for anesthetic gas monitors[J]. Journal of Clinical Monitoring and Computing, 2021,35(5):1069-1076.
|
[10] |
Miller R D, Cohen N H, Eriksson L I, et al. 米勒麻醉学[M]. 8版. 邓小明,常因明,黄宇光,等译. 北京:北京大学医学出版社,2017: 579.
|
|
Han J Z, Chang Y X. Absorption coefficient of optical monocrystalline germanium and its temperature effect[J]. Laser and Infrared, 1983(3):23-26.
|
[17] |
WS/T 656-2019 麻醉机安全管理[S]. 2019.
|
|
Zhang F, Zhang L P. The application of infrared absorption spectroscopy to gas monitoring[J]. Journal of Tangsan Teachers College, 2005, 27(5):62-64.
|
[5] |
Walder B, Lauber R, Zbinden A M. Accuracy and cross-sensitivity of 10 different anesthetic gas monitors[J]. Journal of Clinical Monitoring, 1993, 9(5):364-373.
|
[11] |
刘强. 医用麻醉气体浓度监测系统研制[D]. 成都:电子科技大学, 2005.
|
|
Wu Y S. Discussion on infrared transmission characteristic of monocrystalline germanium[J]. Yunnan Metallurgy, 1991(5):30-36.
|
|
Lü H G, Ma R M, Zhang L, et al. Research on accurate measurement of low concentration nitric oxide in high temperature water-containing flue gas based on FTIR spectrometer[J]. Acta Metrologica Sinica, 2021, 42(4):526-531.
|
[9] |
Christensen P L, Nielsen J, Kann T. Methods to produce calibration mixtures for anesthetic gas monitors and how to perform volumetric calculations on anesthetic gases[J]. Journal of Clinical Monitoring, 1992, 8(4):279-284.
|
[16] |
GB 9706.29-2006 医用电气设备 第2部分 麻醉系统的安全和基本性能专用要求[S]. 2006.
|
|
Liu Q, Yao D Z, Li X S, et al. Anesthesia gas concentration measure device based on NDIR technique[J]. Chinese Medical Equipment Journal, 2005, 26(7):26-27.
|
[15] |
韩季之, 常引秀. 光学用单晶锗的吸收系数及温度对它的影响[J]. 激光与红外, 1983(3):23-26.
|
|
|
|