Accuracy Evaluation of Gravity Continuous Observation at Key Comparison Site of Absolute Gravimeter |
MOU Li-shuang,FENF Jin-yang,WU Shu-qing,LI Chun-jian,WANG Qi-yu |
National Insitute of Metrology, Beijing 100029, China |
|
|
Abstract The uncertainty of continuous observation results of superconduct gravimeter iGrav-012 at the comparison point of the global absolute gravimeter of National Insitute of Metrology is analyzed. The calibration factor of superconduct gravimeter is -927.96(nm/s2)/V, and the uncertainty is 0.80(nm/s2)/V. The uncertainty of continuous observation results of superconduct gravimeter introduced by the calibration factor is 3.20 nm/s2. After 5.5 years′ observation at the same site of superconduct gravimeter and absolute gravimeter, the drift rate of superconduct gravimeter is -14.66(nm/s2)/year, and the uncertainty is 2.1(nm/s2)/year. The uncertainty of continuous observation results of superconduct gravimeter introduced by the drift is 6.30nm/s2, and the uncertainty introduced by the two variables to the continuous gravity observation results is 7.07nm/s2.
|
Received: 26 September 2021
Published: 28 December 2022
|
|
|
|
|
[1]Crossley D, Hinderer J, Riccardi U . The measurement of surface gravity[J]. Reports on Progress in Physics, 2013, 76(4):046101.
[2]Faller J E. Thirty years of progress in absolute gravimetry: a scientific capability implemented by technological advances[J]. Metrologia, 2002, 39(5):425.
[3]张为民, 王勇, 周旭华. 我国绝对重力观测技术应用研究与展望[J]. 地球物理学进展, 2008, 23(1):75-78.
Zhang W M, Wang Y, Zhou X H. Expectation and application study of absolute gravity observation technology in China[J]. Progress in Geophysics, 2008, 23 (1): 75-78.
[4]牟丽爽. 重力比对参考值的精准时间链接技术研究[D]. 杭州: 中国计量大学, 2019.
[5]Suh M, Choi S, 刘建华, 等. 根据重力数据研究黄海周边断裂带在海区的延伸[J]. 地球物理学报, 2002, 45(3): 385-397.
Suh M, Choi S, Liu J H, et al. A Study on The Extension of Fault Zones in Yellow Sea and Its Adjacent Areas Based on Gravity Data[J]. Chinese Journal of Geophysics, 2002, 45(3): 385-397.
[6]许大欣. 利用重力异常匹配技术实现潜艇导航[J]. 地球物理学报, 2005, 48(4):812-816
Xu D X. Using gravity anomaly matching techniques to implement submarine navigation[J]. Chinese Journal of Geophysics, 2005, 48 (4):812-816.
[7]贺前钱, 罗少聪, 孙和平,等. 武汉九峰站地下水变化对重力场观测的影响[J]. 地球物理学报, 2016, 59(8):2765-2772.
He Q Q, Luo S C, Sun H P, et al. The influence of groundwater changes on gravity observations at Jiufeng station in Wuhan[J]. Chinese Journal of Geophysics, 2016, 59(8):2765-2772.
[7]刘善良,吴书清,冯金扬, 等. 第10届全球绝对重力仪关键比对相对重力测量[J]. 计量学报, 2020, 41(2): 198-201.
Liu S L, Wu S Q, Feng J Y, et al. Relative Gravity Measurement Campaign during the 10th International Comparison of Absolute Gravimeters[J]. Acta Metrologica Sinica, 2020, 41(2): 198-201.
[8]Wu S Q, Feng J Y, Li C J, et al. The results of CCM.G-K2.2017 key comparison[J]. Metrologia, 2020, 57(1A):07002.
[9]Schmerge D, Francis O. Set standard deviation, repeatability and offset of absolute gravimeter A10-008[J]. Metrologia, 2006, 43(5):414-418.
[10]Chen X D, Sun H P, Xu H Z, et al. Determination of the Calibration Factor of Superconducting Gravimeter 057 at the Lhasa Station: A frequency-Domain Approach[J]. Terrestrial Atmospheric & Oceanic Sciences, 2013, 24(41):629-636.
[11]贾剑钢, 栾威, 申文斌. iGrav-007超导重力仪的性能分析及对球型自由振荡模态0Sm的检测[J]. 武汉大学学报 (信息科学版), 2015, 40(12):1683-1689.
Jia J G, Luan W, Shen W B. iGrav-007 SG and Detection of the Spherical Free Oscillation Modes 0Sm[J]. Geomatics and Information Science of Wuhan University, 2015, 40(12):1683-1689.
[12]El-Gelil A M, Pagiatakis S, El-Rabbany A. On the Potential of Least Squares Response Method for the Calibration of Superconducting Gravimeters [J]. International Journal of Geophysics, 2012, 5(12):3801-8.
[13]Tamura Y, Sato T, Fukuda Y, et al. Scale factor calibration of a superconducting gravimeter at Esashi Station, Japan, using absolute gravity measurements [J]. Journal of Geodesy, 2004, 78(7,8):481-488.
[14]Riccardi U, Rosat S, Hinderer J. On the Accuracy of the Calibration of Superconducting Gravimeters Using Absolute and Spring Sensors: a Critical Comparison[J]. Pure & Applied Geophysics, 2012, 169(8):1343-1356.
[15]Francis O, Dam T V. Evaluation of the precision of using absolutegravimeters to calibrate superconducting gravimeters[J]. Metrologia International Journal of Scientific Metrology, 2002, 39 (5): 485-488.
[16]孙和平, 陈晓东, 许厚泽, 等. GWR超导重力仪潮汐观测标定因子的精密测定[J]. 地震学报, 2001, 24(6):651-658.
Sun H P, Chen X D, Xu H Z, et al. Accurate Determination of Calibration Factor For Tidal Gravity Observation of a Gwr-Superconducting Gravimeter[J]. Acta Seismologica Sinica.2001, 24(6):651-658.
[17]邢乐林, 李辉, 刘子维等. 利用绝对重力测量精密测定超导重力仪的格值因子[J]. 大地测量与地球动力学, 2010, 30(1):48-50.
Xing L L, Li H, Liu Z W, et al. Scale Factor Calibration of A Superconducting Gravimeter by Using Absolute Gravimetery[J]. Journal of Geodesy and Geodynamics, 2010, 30(1):48-50.
[18]Imanishi Y, Higashi T, Fukuda Y. Calibration of the superconducting gravimeter T011 by parallel observation with the absolute gravimeter FG5 #210-a Bayesian approach[J]. Geophysical Journal International, 2002, 151(3):867-878.
[19]Francis O, Niebauer T M, Sasagawa G, et al. Calibration of a superconducting gravimeter by comparison with an absolute gravimeter FG5 in Boulder[J]. Geophysical Research Letters, 1998, 25(7):1075-1078.
[20]Rosat S, Boy J P, Ferhat G, et al. Analysis of a 10-year (1997~2007) record of time-varying gravity in Strasbourg using absolute and superconducting gravimeters: New results on the calibration and comparison with GPS height changes and hydrology[J]. Journal of Geodynamics, 2009, 48(3-5):360-365.
[21]Meurers B. Superconducting Gravimeter Calibration by CoLocated Gravity Observations: Results from GWR C025[J]. International Journal of Geophysics, 2012:1-12.
[22]Francis O, Hendrickx M. Calibration of the LaCoste-Romberg 906 by Comparison with the Superconducting Gravimeter C021 in Membach (Belgium) [J]. Journal of the Geodetic Society of Japan, 2001, 47(1):16-21.
[23]Francis O, Dam T V. Evaluation of the precision of using absolutegravimeters to calibrate superconducting gravimeters [J]. Metrologia International Journal of Scientific Metrology, 2002, 39(5):485-488.
[24]张锐, 韦进, 刘子维, 等. 用SGC053超导重力仪观测资料对gPh058重力仪格值的精密测定 [J]. 大地测量与地球动力学, 2011, 31(5):151-155.
Zhang R, Wei J, Liu Z W, et al. Accuraty Determenation of Scale Value of gPhone058 Gravimeter by Use of Observations With SGC053 Superconducting Gravimeter [J]. Journal of Geodesy and Geodynamics, 2011, 31(5):151-155.
[25]陈晓东, 孙和平, 刘明, 等. 用GWR-C032超导重力仪观测资料实施对LCR-ET20重力仪格值的精密测定[J]. 测绘学报, 2003, 32(3):219-223.
Chen X D, Sun H P, Liu M, et al. Accurate Determination of the Scale Value of the LCR-ET20 Gravimeter Using Observations Recorded with the GWR-C032 Superconducting Gravimeter [J]. Acta Geodaetica Et Cartographica Sinica, 2003, 32(3):219-223.
[26]Crossley D, Hinderer J, Boy J P . Time variation of the European gravity field from superconducting gravimeters[J]. Geophysical Journal International, 2010, 161(2):257-264.
[27]牟丽爽, 冯金扬, 王启宇, 等. iGrav-012超导重力仪定期格值结果分析 [J]. 计量学报, 2019, 40(3):373-377.
Mou L S, Feng J Y, Wang Q Y, et al. Analysis of Calibration Factor of Superconducting Gravimeter iGrav-012[J]. Acta Metrologica Sinica, 2019, 40(3):373-377. |
|
|
|