Research on the National Voltage Standard for 30 kHz~30 MHz |
HE Zhao,HUANG Jian-ming,TIAN Wei |
National Institute of Metrology, Beijing 100029, China |
|
|
Abstract Based on coaxial thermal voltage converters, the national voltage standard for 30 kHz~30 MHz has been established by National Institute of Metrology (NIM). The results of theoretical analysis and experiments indicate that in the frequency band of 30 kHz to 30 MHz and voltage range 0.1 V to 100 V, the uncertainty is 0.01% to 0.1% (k=2). This accomplishment has filled the gap of the national voltage standard in 1~30 MHz.
|
|
|
|
|
[1]Dierikx E F,Mullem van C J,Vreede de J P M. Key Comparison CCEM-K6. c of AC-DC Voltage Transfer Standards at Selected Frequencies between 1 MHz and 100 MHz[C]//Conference on Precision Electromagnetic Measurements Digest,England,London,2004.
[2]Kinard J R,Cai T X. Determination of AC-DC difference in the 0.1~100 MHz frequency range[J].IEEE Trans Instrum Meas,1989,38(2):360-367.
[3]Kinard J R,Zhen Z,Huang D X,et al.Intercomparison of thermal converters at NIM, NIST, PTB, SIRI, and VSL from 10~100 MHz[J].IEEE Trans Instrum Meas,1993,42(2):618-621.
[4]Mullem van C J,Janssen W J G D,Vreede de J P M. Evaluation of the calculable high frequency AC-DC standard[J].IEEE Trans Instrum Meas,1997,46(2):361-364.
[5]Clark R F,Filipski P S,Paulusse C. Improvements in the NRC AC-DC transfer capabilities[J]. IEEE Trans Instrum Meas,1997,46(2):365-368.
[6]Filipski P S,Clark R F,Paulusse D C.Calorimetric thermal voltage converter as a wideband calculable standard of AC-DC difference[J].IEEE Trans Instrum Meas,1999,48(2):387-390.
[7]Scarioni L,Klonz M,Funck T,et al.Quartz thin-film multijunction thermal converters with built-in tee connector for 100 MHz[J].IEEE Trans Instrum Meas,2007,56(2):571-575.
[8]Scarioni L,Lipe T E,Kinard J R. Design and fabrication of MJTCs on quartz substrates at NIST[J].IEEE Trans Instrum Meas,2009, 58(4):868-871. |
|
|
|