A Precision Phase Angle Measurement System for High Voltage Loss Calibration |
YOU Li1, JIN Hai-bin1, ZHAO Wei2, HOU Xu-wei1 |
1.Department of Metrology, Beijing Orient Institute of Measurement and Test, Beijing 100191, China
2.Division of Electricity and Magnetism, National Institute of Metrology, Beijing 100029, China |
|
|
Abstract To measure the phase angle precisely at high voltage loss calibration, a precision phase angle measurement system was developed based on dual channels digital sampling technology. The system mainly made up of two digitizes, one programmable switches set and one amplitude and phase measurement software to measure phase angle, and expand range through voltage dividers and shunts. The system could be self calibrated automatic, and it can correct system phase measurement errors, so it have excellent measurement performance at different phase angles,and phase measurement error can be verified at low power factor condition,its long term stability is also excellent, and uncertainty is less than 0.0005 degree at 50Hz power frequency. It can fulfill various electron-magnetism measurement applications.
|
Received: 13 September 2019
|
|
|
|
|
1 赵伟.“新型电磁传感及高压损耗计量技术研究”项目获“国家质量基础的共性技术研究与应用”重点专项支持 [J]. 中国计量, 2017, (12): 67.
2 刘静章, 王进旗, 王凤波. 过零检测技术在相位测量中应用[J]. 电子测量技术, 2004, (5): 67-68.
3 邓祖朴. 同频信号相位差的高精度检测[J]. 计算机应用研究, 2009, 26 (7) : 2661-2663.
4 YouL, JinH B, HuZ Y. Experiments for calibrate differential phase measurement system [C]∥ 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016), 2016.
5 RydlerK E, SvenssonS, TarassoV. Voltage dividers with low phase angle errors for a wideband power measuring system [C]∥ 2002 Conference on Precision Electromagnetic Measurements (CPEM 2002): 382.
6 BudovskyI, GibbesA M, ArthurD C. A high-frequency thermal power comparator[J]. IEEE Transactions on Instrumentation and Measurement, 1999, 48(2): 427-430.
7 A40B Series Precision DC and AC Current Shunts [EB/OL]. https:∥ us. flukecal. com/products/electrical-calibration/electrical-standards/a40b-series-precision-dc-and-ac-current-shunts.
8 TH0400 精密交直流同轴分流器[EB/OL]. http:∥ www. tunkia.com/cankaojibiaozhunqi/36. html.
9 LindK, SorsdalT, DesignSlindeH., Modeling, and Verification of High-Performance AC-DC Current Shunts From Inexpensive Components[J]. IEEE Transactions on Instrumentation and Measurement, 2008, 57(1): 176-181.
10 BergstenT, TarassoV, RydlerK E. Precision measurement system for characterisation of phase displacement of voltage dividers up to 1MHz[C]∥ CPEM 2010.
11 ZhangJ T, PanX L, LiuW F, et al.Determination of Equivalent Inductance of Current Shunts at Frequency Up to 200kHz[J]. IEEE Transactions on Instrumentation and Measurement, 2013, 62(6): 1664-1668.
12 JinH B, YouL, HuZ Y, et al. Broadband phase angle calibration device based on digital sampling and DFT interpolation algorithm[C]∥ 2014 XXXIth URSI General Assembly and Scientific Symposium (URSI GASS), 2014. |
|
|
|