Calibration Method Research of Standard Hight-frequency Inductor |
ZHAO Min, LIANG Qiong-chong, LI Sheng-chun |
The Fifth Electronics Research Institute of Ministry of Information Industry, Guangzhou, Guangdong 510610, China |
|
|
Abstract By analyzed of the equivalent circuit of standard hight-frequency inductor and measurement principle of wide frequency RLC meter, a method of tracing calibration of hight-frequency inductor based on the resonance method is proposed. Standard capacitance and precision impedance analyzer are used as the main standard, with a test fixture, and the capacitance measurement and frequency setting ability of precision impedance analyzer are used to accurately calibrate inductance. The experiments on several sets of 5mH~5μH @ 0.1~10MHz hight-frequency inductors (7 for each set) show that the main error source is capacitance measurement error, and the uncertainty of measurement results is 0.1%~0.7%.
|
Received: 12 October 2019
|
|
|
|
|
1 国家质量监督检验总局. GJB 8817—2015 宽量程数字RLC测量仪检定规程[S]. 2015.
2 赵振. 高频电容、 电感测量方法及实现[D]. 成都:电子科技大学, 2015: 12-16.
3 梁琼崇, 王实, 陈彦. 标准高频电感器校准方法探讨[J]. 中国计量, 2017, (2): 107-108.
4 толоров п м , 曹大君. 电感线圈固有电容的直接测量[J]. 电测与仪表,1964, (4): 30-31.
5 张关汉. 电感、 电容标准件频率特性的讨论及其确定方法[J]. 计量技术,1980, (2): 11-15.
6 辜明. 测量标准电感器应注意的几个问题[J]. 电子质量,2013, (11): 71-72. GuM. Some Problems in Standard Inductor Measuring[J]. Electronics Quality, 2013, (11): 71-72. |
|
|
|