A Calibration Method for Large-scale Imaging Probe Measuring Machines Based on Line Scale Stitching |
WANG Bing-he, KANG Yan-hui, SUN Shuang-hua |
National Institute of Metrology, Beijing 100029, China |
|
|
Abstract In order to realize full range calibration of the large-scale imaging probe measuring machines scientifically, a method based on line scale stitchingwas developed. The method using the good repeatability of the imaging probe and the grating scale to get smaller stitching error through specific layout of the line scale. The length measurement error of the full range of XY measuring plane can be detected through this stitching method, which can ensure the accuracy of the whole measuring range. A demonstration for full range calibration of large-scale imaging probe measuring machine was provided, and the experiments and uncertainty analysis verified the feasibility of the method.
|
Received: 20 September 2019
|
|
|
|
|
1 郭天太, 王晓晓, 洪博, 等. 用于影像仪测量误差分离的自校准技术[J]. 光学精密工程, 2015, 23 (1) : 197-205. GuoT Y, WangX X, HongB, et al. Self calibration technology in measuring error separation of imaging instrument [J]. Optics and Precision Engineering, 2015, 23 (1) : 197-205.
2 JJF 1318—2011 影像测量仪校准规范[S].
3 谢树冰. 影像测量仪尺寸测量示值误差的不确定度分析 [J]. 工业计量, 2012, (1): 39-40.
4 孙双花, 薛梓, 王鹤岩. 二维光学标准器校准影像测量仪方法研究[J]. 计量学报, 2014, 35(z1): 14-19. SunS H, XueZ, WangH Y. Image Measuring Instrument Calibration with Two-dimensional Optical Standard[J]. Acta Metrologica Sinica, 2014, 35(z1): 14-19. |
|
|
|