Acta Metrologica Sinica
Current Issue | Archive | Adv Search |
Self-calibration of the Phase Angle Errors of RVDs with Serial-parallel Connection Structure
SHI Zhao-min,ZHANG Jiang-tao,PAN Xian-lin,SONG Ying
National Institute of Metrology, Beijing 100029, China
Download: PDF (1006 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  A set of coaxial resistive voltage dividers (RVDs) with serial-parallel connection was designed, and a new method was also proposed to calibrate phase angle errors of RVDs at frequencies up to 100 kHz.The method was mainly based on a special proportional relationship with the resistance and capacitance between two RVDs with identical structure.The absolute phase angle error of a RVD can be derived from the phase difference between the two RVDs.The RVD with ratio of 100:1 consisting of 100 Ω resistive elements was built and self-calibrated with the new method at frequencies from 400 Hz to 100 kHz.The measurement uncertainties was also evaluated.The standard uncertainty in phase angle error of the 1001 RVD consisting of 100 Ω resistive elements was within 30 μrad at 100 kHz.
Key wordsmetrology      AC power standard      resistive voltage divide      phase angle errors      serial-parallel connection structure      self-calibration     
PACS:  TB971  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
SHI Zhao-min
ZHANG Jiang-tao
PAN Xian-lin
SONG Ying
Cite this article:   
SHI Zhao-min,ZHANG Jiang-tao,PAN Xian-lin, et al. Self-calibration of the Phase Angle Errors of RVDs with Serial-parallel Connection Structure[J]. Acta Metrologica Sinica, 2020, 41(3): 301-.
URL:  
http://jlxb.china-csm.org:81/Jwk_jlxb/EN/10.3969/j.issn.1000-1158.2020.03.06     OR     http://jlxb.china-csm.org:81/Jwk_jlxb/EN/Y2020/V41/I3/301
Copyright © Editorial Board of Acta Metrologica Sinica
Supported by:Beijing Magtech