Research on the Traceability Technology of VOR Signal |
HE Zhao,ZHANG Yi-chi,GUO Xiao-tao,HUANG Jian-ming,NIE Mei-ning,TAO Yi |
National Institute of Metrology, Beijing 100029, China |
|
|
Abstract Based on a phase generator and frequency modulation (FM) / amplitude modulation (AM) instruments, a standard very high frequency omnidirectional range (VOR) signal generator is established to realize the traceability of VOR phase quantity to the national phase standard, which cannot be achieved using traditional method of direct digital synthesizing. According to the uncertainty analysis, the extended uncertainty of VOR phase is less than ±0.020° (k=2), while that of VOR modulation depth is ±0.2% (k=2). This standard VOR signal generator can be used to calibrate commercial avionic instruments for VOR signal generation and demodulation.
|
Received: 20 September 2019
Published: 17 February 2020
|
|
|
|
|
[1]孙亚伟, 黄家成, 曹乃森. 甚高频全向信标(VOR) / 仪表着陆系统(ILS) 标准信号源设计 [J]. 电子测量技术. 2008, 31(7): 59-62.
Sun Y W, Huang J C, Cao N S. Standard Signal Source Design for VHF Omnidirectional Beacon / Instrument Landing System [J]. [WTBX][STBX]Electronic Measurement Technology[STBZ][WTBZ], 2008, 31(7): 59-62.
[2]孙亚伟, 黄家成, 元洪波. 采用DSP处理器的甚高频全向信标/仪表着陆系统标准信号源 [J]. 电光与控制. 2009, 16(7): 92-96.
Sun Y W, Huang J C, Yuan H B. Standard Signal Source for VHF Omni Directional Beacon / Instrument Landing System Based on DSP [J]. [WTBX][STBX]Electronics Optics and Control[STBZ][WTBZ], 2009, 16(7): 92-96.
[3]BIPM. Calibration and Measurement Capabilities, Electricity and Magnetism, United States, NIST (National Institute of Standards and Technology) [EB]. https://kcdb.bipm.org/appendixC/EM/CN/EM_CN.pdf.
[4]梁志国. 一种基于残周期正弦波拟合的相位差测量方法 [J]. 计量学报[STBZ][WTBZ], 2016, 37(4): 419-422.
Liang Z G. The Phase Difference Evaluation Based on Total Least-square Method with Partial Period Sinusoidal Waveforms [J]. [WTBX][STBX]Acta Metrologica Sinica[STBZ][WTBZ], 2016, 37(4): 419-422.
[5]梁志国. 正弦波拟合参数的不确定度评定 [J]. 计量学报, 2018, 39(6): 888-894.
Liang Z G. The Measurement Uncertainty of Curve-fit Parameters of Sinusoidal [J]. [WTBX][STBX]Acta Metrologica Sinica[STBZ][WTBZ], 2018, 39(6): 888-894.
[6]何昭, 张亦弛, 郭晓涛, 等. 仪表着陆系统信号量值溯源技术研究 [J]. 计量技术. 2016, (9): 39-42.
He Z, Zhang Y C, Guo X T, et al. Research on Traceability Technology of Instrument Landing System Signal Quantity [J]. [WTBX][STBX]Measurement Technique[STBZ][WTBZ], 2016, (9): 39-42.
[7]陈凌峰. 标准不确定度A 类评定中极差法的深入讨论 [J]. 计量学报, 2019, 40(2): 347-452.
Chen L F. The Further Discussion of the Range Method in the Type A Evaluation of Standard Uncertainty [J]. [WTBX][STBX]Acta Metrologica Sinica[STBZ][WTBZ], 2019, 40(2): 347-452.
[8]梁志国, 孟晓风. FM信号源调制相移特性和调制延迟的测量评价 [J]. 计量技术, 2007, (7): 5-7.
Liang Z G, Meng X F. Measurement Evaluation of FM Signal Source Phase Shift and Delay [J]. [WTBX][STBX]Measurement Technique[STBZ][WTBZ], 2007, 7: 5-7. |
|
|
|