|
|
Study on Electromagnetic Flowmeter Sensor Signals Based on Two-phase Flow |
KONG Ling-fu1, WANG Yue-ming1,2, LI Ying-wei1, LIU Xing-bin3, ZHANG Yu-hui3 |
1.College of Information Science & Engineering, Yanshan University, Qinhuangdao, Hebei 066004, China;
2.School of MPB, Inner Mongolia University of Science and Technology, Baotou, Neimonggu 014010, China;
3.Daqing Logging and Testing services Company, Daqing, Heilongjiang 163000, China |
|
|
Abstract The electromagnetic flow meter is widely used in the two-phase flow measurements of oil and water in recent years. Since the non-conductive material exists in the two-phase flow of oil-water, the non-conductive material has some impacts on measurement of the flow meter. The simulation model of magnetic field distribution is built by the finite element software ANSYS, and the non-conductive material on the weighting function effect of the electromagnetic flow meter is discussed. The simulation model of the fluid is established by FLUENT. Furthermore, the relationship between different flow rates and water contents with response characteristics of electromagnetic flowmeter is analyzed. The simulation result is verified by experiments in the Simulation Wells.
|
|
|
|
|
[1] Abduvayt P, Manabe R, Watanabe T. Analysis of Oil-Water Flow Tests in Horizontal, Hilly-Terrain, and Vertical Pipes[J]. Society of Petroleum Engineers, 2006,(3): 123-133.
[2] 宗艳波,金宁德,王振亚.倾斜油水两相流水为连续相的逆塞流及过渡流型非线性特性[J].计量学报,2008,29(5):449-453.
[3] Wang Y M, Kong L F. The study on the Effect of virtual current distribution in an electromagnetic flow meter with bubble[C]//MACE 2011.The 2nd International Conference on Mechanic Automation and Control Engineering. Hohhot .2011: 885 – 887.
[4] Bernier R N, Brennan C E. Use of the electromagnetic flowmeter in a two-phase flow[J]. Int J Multiphase Flow, 1983,9: 251-257.
[5] 蔡武昌,马中元,瞿国芳,等.电磁流量计[M].北京:中国石化出版社, 2004,1-75.
[6] 孙作达, 吴凯滨,郑培智,等.基于分子磁化率性质的电磁流量计误差[J].哈尔滨商业大学学报(自然科学版),2010,26(4):459-461.
[7] Zhang X Z, Li Y T. Calculation of the virtual current in an electromagnetic flow meter with one bubble using 3D model[J]. ISA Transactions, 2004, 43(2): 189-194.
[8] Zhang X Z. On finding the virtual current in an electromagnetic flow meter containing a number of bubbles by two dimensional analysis [J]. Meas Sci Technol, 1999,(10):1087-1091.
[9] Li Y W, Kong L F, Liu L B. Virtual Current Characteristics of Electromagnetic Flow with spherical Bubbles[J]. Journal of Computational Information Systems,2011,7(3):762-769.
[10] 张玉辉,刘兴斌,单福军,等.电磁法测量高含水油水两相流流量实验研究[J].测井技术,2011,35(3):206-209. |
|
|
|