Uncertainty Analysis for Spectral Radiant Intensity Measurements of LEDs |
YIN De-jin, LIU Wei, LAI Lei, HUANG Bi-yong, LI Tie-cheng |
Shanghai Institute of Measurement and Testing Technology, Shanghai 201203, China |
|
|
Abstract Uncertainties associated with measurements of LEDs are extremely important.By choosing specific quantities,devices under test and equipments, the process of uncertainty budgets by example can be analyzed.Spectroradiometer measurements are traceable to NIM spectral irradiance scale.The particular LED was chosen because it also has an independent NIM traceable calibration via another path and can provide verification of measurements.The uncertainty of spectral radiant intensity measurements of LEDs is analyzed through experiment and calculation.
|
|
|
|
|
[1] CIE 127,Measurement of LEDs[S].1997.
[2] 吴宝宁,等.LED光学参数测试方法研究[J].应用光学,2007,28(4):513~516.
[3] 叶荣南.LED测量误差探讨[J].现代显示,2007,(9):21~25.
[4] 吕正,樊其明,吕亮.LED光通量测量中的自吸收效应及校正[J].照明工程学报,2006,17(2):16~17.
[5] 吕正.NIST对LED发光强度的测量[J].中国照明电器,2006,(8):29~31. |
|
|
|