Preliminary Study on Influence of Installation Conditions on Measuring Accuracy of Ultrasonic Flowmeters |
HAN Wei,CHEN Xing-chuan,ZHANG Huo-jian,WANG Duo-cai,ZHOU Lei |
Petrochina West East Gas Pipeline Nanjing Measurement Testing Center, Nanjing, Jiangsu 210058, China |
|
|
Abstract The effects of different installation conditions on measuring accuracy of ultrasonic flowmeter were studied by means of experimental test and numerical simulation. The experimental results show that the rusted straight pipe section and whether or not to install flow conditioner and which flow conditioner to install have a great influence on the flow state and measurement results. The numerical simulation results support the experimental results. In order to ensure the accuracy and reliability of the trade handover, the verification and on-site use and installation should meet the standard requirements. If the consistency cannot be achieved, it is suggested to submit the supporting accessories of the flow meter for inspection together.
|
|
|
|
|
|
[1]Lynnworth L C, Liu Y. Ultrasonic flowmeters: Half-century progress report, 1955—2005[J]. Ultrasonics, 2006, 44:e1371-e1378.
[2]王存伟. 气体超声流量计在天然气流量计量中的应用分析[J]. 石油化工自动化, 2015 , 51 (6) :69-72.
Wang C W. Application Analysis of Gas Ultrasonic Flowmeter in Natural Gas Flow Measurement [J]. Automation in Petro-Chemical Industry, 2015 , 51 (6):69-72.
[3]陈松, 黄坤, 马国光, 等. 用于天然气流量计量的超声流量计[J].油气储运 , 2002 , 21(5):37-40.
Chen S, Huang K, Ma G G, et al. The Ultrasonic Flow Meter Used to Measure Flow Rate of Natural Gas [J]. Oil & Gas Storage and Transportation, 2002 , 21(5):37-40.
[4]Franchini S, A, Sanz-Andrés, Cuerva A. Measurement of velocity in rotational flows using ultrasonic anemometry: the flowmeter[J]. Experiments in Fluids, 2007, 42(6):903-911.
[5]Holden J L, Peters R J W. Practical experiences using ultrasonic flowmeters on high pressure gas [J]. Flow Measurement & Instrumentation, 1991, 2(1):69-73.
[6]杨声将, 何敏, 任佳. 超声波流量计计量系统性能的主要影响因素[J]. 天然气工业, 2006, 26(3):111-113.
Yang S J, HE M, Ren J. Main Factors Impacting Perform ances of Ultrasonic Flowmeter Measurement System[J]. Natural Gas Industry, 2006, 26(3):111-113.
[7]郑传波, 许潘文, 黄冠文, 等. 温度偏差对天然气流量计检定结果的影响[J]. 计量学报, 2016, 37(6A):190-193.
Zheng C B, Xu P W, Huang G W, et al. Effect of Temperature Deviation on Natural Gas Flow-meter Verification Results[J]. Acta Metrologica Sinica, 2016, 37(6A):190-193.
[8]ZHANG D D, ZHANG P Y, XU T S. Effect of Installation Position of Ultrasonic Flowmeter Probe on Flow Measuremen[J]. Journal of Mechanical Engineering, 2011, 28(3):232-237.
[9]王宏伟, 李高峰, 朱成义. 气体流量计检定过程中的影响因素分析[J]. 计量学报, 2012, 33(z1):170-173.
Wang H W, Li G F, Zhu C Y. Analysis of the Affect Factors in Process of Gas Flowmeter Calibration [J]. Acta Metrologica Sinica, 2012, 33(z1):170-173.
[10]国家质量检督检验总局. GB/T 18604—2014 用气体超声流量计测量天然气流量 [S]. 2014.
[11]国家质量检督检验总局. JJG 1030—2007 超声流量计 [S].2007. |
|
|
|