Volume Measurement Method of Vertical Metal Tank Based on Laser Scanning |
HAO Hua-dong,LI Cun-jun,LIU Ying,SHI Hao-lei,LI Shu-guang |
Zhoushan Institute of Calibration and Testing for Qualitative and Technical Supervision, Zhoushan, Zhejiang 316021, China |
|
|
Abstract According to the traditional large capacity measurement methods have some shortcomings, such as low accuracy, low work efficiency and labor intensity, a volume measurement method for vertical metal tank based on laser scanning is presented. The volume calculation model is established for vertical tank and the concrete implementation process is analyzed. And the key algorithms are researched for the laser point cloud data analysis and process. The volume value is automatically calculated in the different liquids by calculating the cross-sectional area along the horizontal direction of tank and integrating from vertical direction. A vertical tank is selected as the measurement object, which has the nominal capacity of 1000 m3. It is shown the good repeatability and reappearance of the proposed method. To design an experimental comparison system, the measurement experiment is carried out in three different vertical tanks which has the nominal capacity of 1000 m3, 2500 m3 and 5000 m3, respectively. The maximum relative deviation of volume measurement between the proposed method and total station method is 0.0729%, 0.0329% and 0.0582%, respectively.
|
Received: 09 November 2017
Published: 11 February 2018
|
|
|
|
|
[1]刘子勇.容量计量[M].北京:中国计量出版社,2009:11.
[2]JJG 168—2005 立式金属罐容量计量检定规程[S]. 2005.
[3]ISO 7507—1—2003 Petroleum and liquid petroleum products volumetic calibration of vertical cylindrical tanks[S].2003:6-11.
[4]ISO 7507—2—2005 Petroleum and liquid petroleum products volumetric calibration of vertical cylindrical tanks part2:optical reference line method[S]. 2005:6-16.
[5]ISO 7507—4—2010 Petroleum and liquid prtroleum products volumetric calibration of vertical cylindrical tanks part4:Internal electro-optical distance-ranging method [S]. 2010:1-7.
[6]OIML R71 2008 Fixed storage tanks General requirements[S]. 2008:11-18.
[7]廉育英, 刘子勇, 何力, 等. 立式金属计量罐大容量的新测量方法[J].计量学报, 1988,9(4):241-247.
[8]王金涛, 刘子勇, 张珑, 等. 基于点云分析的大型立式液态石化产品储罐容量计量方法研究[J].计量学报, 2011, 32(2):110-113.
[9]Nosach V V, Belyaev B M. The Calibration of Large Vertical Cylindrical Tanks by a Geometrical Method [J].Measurement Techniques,2002,45(22):1153-1157.
[10]吴斌,丁文,杨峰亭,等. 非正交轴系全站仪坐标测量系统误差分析技术研究[J]. 计量学报, 2017,38(6):661-666.
[11]佟贵新, 郑鹤, 彭元博, 等. 容量比较法检定罐容案例分析及研究[J]. 中国计量, 2017, (7):104-105.
[12]赵庆阳. 三维激光扫描仪数据采集系统研制[D]. 西安:西安科技大学, 2008.
[13]魏凯, 宋述古, 刘子勇. 基于三维激光扫描原理的球形罐容量计量方法研究[J]. 计量学报, 2015, 36(6):607-609.
[14]罗大兵, 高明, 王培俊. 逆向工程中数字化测量与点云数据处理[J].机械设计与制造, 2005, (9):56-58.
[15]佟林, 王金涛, 刘子勇, 等. 基于光电内测法的立式罐容量计量中圈板半径拟合算法的研究[J]. 计量学报, 2011,32(6):522-525. |
|
|
|