Signal Processing Methods of Coriolis Mass Flowmeter for Measurement of the Frequent Starting and Stopping Flow |
LIU Cui1, XU Ke-jun 1,2 , HOU Qi-li1, XIONG Wen-jun1, FANG Min1 |
1.School of Electrical and Automation Engineering, Hefei University of Technology, Hefei, Anhui 230009, China;
2.Engineering Technology Research Center of Industrial Automation, Hefei, Anhui 230009, China |
|
|
Abstract According to the characteristic of the frequent starting and stopping flow, a mutation-signal mode of Coriolis mass sensor is proposed to describe the change patterns of signal parameters with the sudden change of flow. The exiting DTFT algorithm with negative frequency contribution is evaluated using this model, and its errors are analyzed in the batch applications. On the basis of these studies, this algorithm is improved to apply to processing of the mutation signal. The algorithm is implemented in real time in a DSP-based digital Coriolis mass flow transmitter developed, and water flow calibrations consisting of starting-stopping flow method and steady-flow method are performed for the transmitter. The experimental results show that the method has both fast dynamic response and highed measurement accuracy.
|
|
|
|
|
[1] Henry M P, Clarke D W, Vignos J H. Digital flowmeter. U S, 2002/0038186 A1[P].2002-05-28.
[2] Henry M P, Clarke D W, Archer N, et al . A self-validating digital Coriolis mass-flow meter: an overview[J]. Control Engineering Practice ,2000,8:487-506.
[3] 徐科军,张瀚.一种科氏流量计的数字信号处理与驱动方法研究[J].计量学报,2004,25 (4):339-343,379.
[4] 徐科军,倪伟.一种科里奥利质量流量计的信号处理方法[J]. 计量学报,2001,21(4):254-258.
[5] 郑德智,樊尚春,邢维巍.科氏质量流量计相位差检测新方法[J].仪器仪表学报,2005,26(5):441-443.
[6] 徐科军,徐文福.基于AFF和SGA的科氏质量流量计信号处理方法 [J].计量学报,2007,28(1):48-51.
[7] 徐科军,倪伟,陈智渊.基于时变信号模型和格型陷波器的科氏流量计信号处理方法[J].仪器仪表学报,2006,27(6):596-601.
[8] 朱志海,徐科军,杨双龙,等.面向时变信号模型的科氏质量流量传感器信号处理方法的实现与测试[J].计量学报,2010,31(4):325-329.
[9] 张海涛,涂亚庆.计及负频率影响的科里奥利质量流量计信号处理方法[J].仪器仪表学报,2007,28(3):539-544.
[10] 李叶,徐科军,朱志海,等.面向时变的科里奥利质量流量计信号处理的方法研究与实现[J].仪器仪表学报,2010,31(1):8-14.
[11] 侯其立,徐科军,李叶,等.基于TMS320F28335的高精度科氏质量流量变送器研制 [J].仪器仪表学报,2010,31(12):2788-2795.
[12] Cheesewright R, Clark C, Belhadj A, et al . The dynamic response of Coriolis mass flow meters[J]. Journal of Fluids and Structures, 2003, 18:165-178.
[13] Henry M P, Clark b C, Duta M, et al . Response of a Coriolis mass flow meter to step changes in flow rate[J]. Flow Measurement and Instrumentation, 2003, 14:109-118.
[14] Clark C, Cheesewright R. Experimental determination of the dynamic response of Coriolis mass flow meters[J]. Flow Measurement and Instrumentation, 2006, 17: 39-47.
[15] Jacobsen E, Lyons R. The sliding DFT[J]. IEEE Signal Processing Magazine, 2003,20(3):74-80. |
|
|
|