Research on Automated Calibration of Hydraulic Piston Gauges
WANG Bowen1,YANG Yuanchao1,PANG Guibing2,MA Kun1,YUE Jin1,HUANG Qian1
1. National Institute of Metrology,Beijing 100029,China
2. College of Mechanical Engineering and Automation,Dalian Polytechnic University, Dalian,Liaoning 116034, China
Abstract:Using a high-resolution pressure transducer, an automated calibration system for hydraulic piston gauges in the range of 1~120 MPa has been developed based on the theoretical analysis, manifold design and programming. The transducers' linear coefficients and its long-term stability were tested, and the results showed that the deviations of linear coefficients from 1 were less than ±4×10-4. Comparing with the traditional calibration method, the reliability of the developed system for the dissemination of pressure SI-unit from the NIM primary pressure standard has been demonstrated. The calibration results by two methods, the so-called Δp-method and p-method, were compared using the automated system, and the consistency of the two methods was verified. By using the automated system for the calibration of hydraulic piston gauges, the relative expanded uncertainty of the calibrated effective area is 32×10-6 (k=2), and the expanded uncertainty of the calibrated distortion coefficient is 1.8×10-7 /MPa(k=2). The time required for calibration is significantly reduced compared to traditional methods.
YANG Y C, YUE J. Calculation of Effective Area for the NIM Primary Pressure Standards [J]. PTB Mitteilungen, 2011, 121(3): 266-269.
WANG B W, MA K, DONG J, et al. Theoretical Calculations for Distortion Coefficient of Piston Gauge Based on Finite Element Analysis [J]. Acta Metrologica Sinica,2024,45(10):1525-1532.
SHENG Y T, HUANG G Z, HAN H W, et al. An International Comparison of Pressure in the Range of 20~100 MPa [J]. Acta Metrologica Sinica, 1988, 9(2): 88-94.
[8]
RAB S, ZAFER A, SHARMA R K, et al. National and Global Status of the High Pressure Measurement and Calibration Facilities [J]. Indian J Pure Appl Phys, 2022, 60(1): 38-48.
[10]
蒋思敬, 姚士春. 压力计量 [M]. 北京: 中国计量出版社, 1991.
[12]
KOBATA T, OLSON D A. Accurate determination of equilibrium state between two pressure balances using a pressure transducer [J]. Metrologia, 2005, 42(6): S231-S4.
YANG Y C.Research on Automated Calibration Method for Piston Gauges [J]. Acta Metrologica Sinica, 2017, 38 (6): 708-712.
ZENG L, YANG Y C, YUE J, et al. Research on Automated Dissemination of Primary Standard for Pneumatic Piston Gauges [J]. Acta Metrologica Sinica, 2021, 42(10): 1316-1322.
OLSON D A. NIST calibration services for pressure using piston gauge standards [R]. Gaithersburg, MD: National Institute of Standards and Technology, 2009: 47-48.
YANG Y C, YUE J, LI Y H. The Effective Area and Distortion Coefficient of CCM.P-K13 Transfer Standard and the Analysis of Uncertainty [J]. Acta Metrologica Sinica, 2011, 32(5): 441-5.
PANG G B, YANG Y, FAN S J, et al. Measurement Errors of Piston Pressure Gauge for Mass Weights and Pressure Weights.[J]. Acta Metrologica Sinica, 2023 , 44 (12): 1842- 1846.
[11]
DADSON R S, LEWIS S, PEGGS G N. The Pressure Balance, Theory and Practice [M]. London: National Physical Laboratory, 1982.
[13]
KOBATA T. A fully automated calibration system for pressure balance[C] // IMEKO 20th TC3, 3rd TC16 and 1st TC22 Int. Conf. Cultivating metrological knowledge. Merida, Mexico, 2007
THAKUR V N, YADAV S, KUMAR A. Evaluation of Uncertainty in the Effective Area and Distortion Coefficients of Air Piston Gauge Using Monte Carlo Method [J]. MAPAN-J Metrol Soc India, 2019, 34(3): 371-377.
WANG C, LIU H Y, YANG Y C, et al. Design of Key Parameters of Piston-cylinder Assembly of 500 MPa Piston Pressure Gauge [J]. Acta Metrologica Sinica, 2021, 42(12): 1625-9.
[9]
SCHERSCHLIGT J, OLSON D, DRIVER R G, et al. Pressure balance cross-calibration method using a pressure transducer as transfer standard [J]. NCSL International measure, 2016, 11(1): 28-33.
YANG Y C, DRIVER R G, QUINTAVALLE J S, et al. An integrated and automated calibration system for pneumatic piston gauges [J]. Measurement, 2019, 134: 1-5.
WANG B W, YANG Y C, YANG Y, et al. Uncertainty Evaluation on the Effective Area of Piston Gauge using Monte Carlo Method [J]. Metrology Science and Technology, 2024, 68(7):63-71.
GUO Y G, HUANG D L, FANG Y Y, et al. A Transportable Laser Interferometry Absolute Gravimeter Type NIM-Ⅱ [J]. Chinese Journal of Geophysics, 1988, 31(1): 73-81, 121.