2025年04月15日 星期二 首页   |    期刊介绍   |    编 委 会   |    投稿指南   |    期刊订阅   |    统合信息   |    联系我们
计量学报  2024, Vol. 45 Issue (9): 1257-1261    DOI: 10.3969/j.issn.1000-1158.2024.09.02
  热学计量 本期目录 | 过刊浏览 | 高级检索 |
温度传感器动态响应校准恒温恒速水槽研究
郑伟1,刘波1,王志远2
1.上海市计量测试技术研究院,上海201203
2.上海理工大学能源与动力工程学院,上海200093
Research of Constant Temperature and Velocity Water Bath for Calibration of Temperature Sensors Dynamic Response
ZHENG Wei1,LIU Bo1,WANG Zhiyuan2
1. Shanghai Institute of Measurement and Testing Technology, Shanghai 201203, China
2. School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
全文: PDF (442 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 动态响应是安全重要场合温度传感器的关键性能,恒温恒速水槽是温度传感器水流环境动态响应校准的核心设备。针对典型环形旋转水槽升温慢的问题,研制了基于精密滑环的电加热环形旋转水槽,开展了温场性能和流场性能测试,并与现有射流旋转水槽温度传感器动态响应校准装置的结果进行了比较。结果表明,新研制的基于精密滑环的电加热环形旋转水槽升温时间缩短,温度波动度显著小于温度阶跃量的±1.0%,竖直方向流速均匀度显著优于10%的要求。对铠装热电阻和热电偶时间常数进行了测量,与现有装置测量结果的偏差分别为4.1%和7.5%,满足工程应用要求,为温度传感器动态响应校准提供了良好的恒温恒速环境条件。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
郑伟
刘波
王志远
关键词 温度计量温度传感器动态响应时间常数恒温恒速水槽    
Abstract:Dynamic response is a key performance of temperature sensors in important and safety occasions. The constant temperature and velocity water bath is the core equipment for the calibration of temperature sensors dynamic response. Due to the slow heating rate in typical annular rotating water bath, a novel electrically heated annular rotating water bath was developed based on the precision sliding ring, and the temperature fluctuations and velocity fields of the novel bath were tested. The results show that the heating up time is shortened, the temperature fluctuation is significantly less than ±1.0% of the step temperature, the vertical velocity uniformity is significantly better than 10% of the novel bath. The time constants of a sheathed resistance thermometer and a sheathed thermocouple were measured by the existing jet rotating water bath and the novel bath. The deviations from the existing bath results are 4.1% and 7.5%, respectively, these meet the engineering requirement. The novel bath provides good constant temperature and velocity environmental conditions for the dynamic response calibration of temperature sensors.
Key wordstemperature measurement    temperature sensor    dynamic response    time constant    constant temperature and velocity water bath
收稿日期: 2024-02-05      发布日期: 2024-09-26
PACS:  TB942  
基金资助:上海市市场监督管理局科技项目(2022-21)
通讯作者: 刘波(1988-),山东平邑人,上海市计量测试技术研究院高级工程师,博士,主要从事温度计量研究。Email: liubo021@126.com     E-mail: liubostudentecust@163.com
作者简介: 郑伟(1972-),上海人,上海市计量测试技术研究院工程师,主要从事温度计量研究。Email: zhengw@simt.com.cn。
引用本文:   
郑伟,刘波,王志远. 温度传感器动态响应校准恒温恒速水槽研究[J]. 计量学报, 2024, 45(9): 1257-1261.
ZHENG Wei,LIU Bo,WANG Zhiyuan. Research of Constant Temperature and Velocity Water Bath for Calibration of Temperature Sensors Dynamic Response. Acta Metrologica Sinica, 2024, 45(9): 1257-1261.
链接本文:  
http://jlxb.china-csm.org:81/Jwk_jlxb/CN/10.3969/j.issn.1000-1158.2024.09.02     或     http://jlxb.china-csm.org:81/Jwk_jlxb/CN/Y2024/V45/I9/1257
京ICP备:14006989号-1
版权所有 © 《计量学报》编辑部
地址:北三环东路18号(北京1413信箱)  邮编:100029 电话:(010)64271480
本系统由北京玛格泰克科技发展有限公司设计开发  技术支持:support@magtech.com.cn